Akselrod S, Norymberg M, Peled I. et al. (1987) Computerized analysis of ST segment changes in ambulatory electrocardiograms. Medical and Biological Engineering and Computing, 25,513–519.

Armstrong WF, Morris SN. (1983) The ST segment during ambulatory electrocardiographic monitoring. Annals of Internal Medicine, 98, 249–250.

Augustyniak P. (1999) Recovering The Precise Heart Rate From Sparsely Sampled Electrocardiograms, Computers in Medicine, str. 59–65

Badilini F, Zareba W, Titlebaum EL, Moss AJ. (1986) Analysis of ST segment variability in Holter recordings. [w:] Moss A, Stern A. (red.) Noninvasive electrocardiology—clinical aspects of Holter monitoring. London: Saunders Co.

Bailon R, Olmos S, Serrano P, Garcıa J, Laguna P. (2002) Robust Measure of ST/HR Hysteresis in Stress Test ECG Recordings, Computers in Cardiology, 29:329−332.

Biagini A, Mazzei MZ, Carpeggiani C. et al. (1982) Vasospastic ischemic mechanism of frequent asymptomatic transient ST-T changes during continuous electrocardiographic monitoring in selected unstable patients. American Heart Journal, 103, 4–12.

Cosby RS, Herman LM. (1962). Sequential changes in the development of the electrocardiographic pattern of left ventricular hypertrophy in hypertensive heart disease. American Heart Journal, 63, 180.

Daskalov IK, Dotsinsky IA, Christov II. (1998) Development in ECG acquisition, preprocessing, parameter measurement, and recording. IEEE Engineering in Medicine and Biology Magazine, 17(2): 50–58.

Drew BJ, Califf RM, Funk M, Kaufman ES, Krucoff MW, Laks MM, Macfarlane PW, Sommargren C, Swiryn S, Van Hare GF. (2004) Practice standards for electrocardiographic monitoring in hospital settings. An American Heart Association Scientific Statement from the Councils on Cardiovascular Nursing, Clinical Cardiology, and Cardiovascular Disease in the Young. Circulation, 110: 2721–2746. (tłumaczenie dostępne w Medycyna Praktyczna 2005/05, http://www.mp.pl/artykuly/index.php?aid= 26720&_tc =3EA6F810994B4F859548009D3C37EFC1)

Favretto FO, Farias CRG, Murta LO Jr. (2007) A Decision Support System for Ischemic Event Detection. Computers in Cardiology, 34:213−216.

Hull E. (1961) The electrocardiogram in pericarditis. American Journal of Cardiology, 7, 21.

Jager F, Taddei A, Moody GB, Emdin M, Antolic G, Dorn R, Smrdel A, Marchesi C, Mark RG. (2003) Long-term ST database: a reference for the development and evaluation of automated ischaemia detectors and for the study of the dynamics of myocardial ischaemia. Med Biol Eng Comp. 41:172–182.

Lehtinen R, Sievanen H, Viik J, Turjanmaa V, Niemela K, Malmivuo J. (1996) Accurate detection of coronary artery disease by integrated analysis of the ST-segment depression/heart rate patterns during the exercise and recovery phases of the exercise ECG test. American Journal of Cardiology, 78(9):1002–1006.

Moody GB, Mark RG, Zoccola A, Mantero S. (1986) Derivation of respiratory signals from multilead ECGs. Computers in Cardiology, 13:113–116.

Moss AJ. (1986) Clinical utility of ST segment monitoring. [w:] Moss A, Stern S. (red.) Noninvasive electrocardiology—clinical aspects of Holter monitoring.London: Saunders Co.

Nelson SD, Kou WH, Annesley T. (1989) Significance of ST segment depression during paroxysmal superventricular tachycardia. Journal of the American College of Cardiology, 13, 804.

Pang L, Tchoudovski I, Braecklein M, Egorouchkina K, Kellermann W, Bolz A. (2005) Real time heart ischemia detection in the smart home care system. Proc. 27-th International Conference of the IEEE Engineering in Medicine and Biology Society, str. 3703–3706.

Parker JO, di Giorgi S, West RO. (1966) A hemodynamic study of acute coronary insufficiency precipitated by exercise. American Journal of Cardiology 17: 470–483

Pottala EW, Bailey JJ, Horton MR, Gradwohl JR. (1989) Suppression of baseline wander in the ECG using a bilinearly transformed, null-phase filter. Journal of Electrocardiology, 22(suppl): 243–247.

Smrdel A, Jager F. (2008) An Algorithm to Estimate the ST Segment Level in 24-Hour Ambulatory ECG Records. Computers in Cardiology, 35:701−704.

Stern S, Tzivoni D. (1974) Early detection of silent ischemic heart disease by 24-hour electrocardiographic monitoring of active subjects. British Heart Journal, 36:481–486

Tayler DI, Vincent R. (1985) Artefactual ST segment abnormalities due to electrocardiograph design. British Heart Journal, 54:11–28

Wang JY, Saenz MC, Horáček BM. (2003) Comparison of alarm strategies for continuous 12-lead ST segment monitoring. Computers in Cardiology, 30:809–12

Wang JY, Warren JW, Horáček BM. (2004) Sensitivity-Specificity Tradeoff for Different Alarm Strategies in Continuous 12-Lead ST-Segment Monitoring. Computers in Cardiology, 31:721−724

Wang JY. (2000) Noise stress testing for real-time ST segment measurement algorithms: A new methodology. Computers in Cardiology, 27:845–8

Weisner SJ, Tompkins WJ, Tompkins BM. (1982a) A compact, microprocessor- based ECG ST-segment monitor for the operating room. IEEE Trans Biomed Eng. 29:642–649

Weisner SJ, Tompkins WJ, Tompkins BM. (1982b) Microprocessor-based, portable anesthesiology ST-segment analyzer. Proc. Northeast Bioengineering Conference, 222–226